SM SERIES STEAM STERILIZERS – SUMER
Material:
- Body: AISI 304 stainless steel
- Chamber: 6 mm, AISI 316L stainless steel
- Jacket: 3 mm, AISI 316L stainless steel
- Cover: 6 mm, AISI 304 stainless steel
- Panel Coating: AISI 304 stainless steel
- Piping: Brass, AISI 304 stainless steel
The entire piping system can optionally be made from AISI 304 stainless steel.
Control & Monitoring:
- Control System: PLC processor
- Operation Mode: Fully automatic, controlled via buttons and touch screen
- Screen Type: Color TFT, Touch LCD
- Screen Size: 7.0″ (Optional: 10.0″)
- Keypad: Touch Screen
- Printer: Integrated thermal printer (40 characters per line)
- Communication: RS232 / 485 Port – USB (Optional: Ethernet)
- Warning System: Audiovisual and written messages
- Data Storage: Up to 200 cycles
- Procedure Tracking: Analog indicators for cell, jacket, generator, and air pressure in addition to the touch screen
- Mobility: Easy movement with 4 swivel castors and adjustable stabilization legs
- Steam Control: Through pneumatic valves
Standard Programs
Program Type | Temperature | Duration |
Medical and Surgical Tools | 134°C | ~60 min |
Textile Materials | 134°C | ~60 min |
Heavy Materials | 134°C | ~65 min |
Plastic/Rubber Materials | 121°C | ~80 min |
Rubber/Glass | 125°C | ~60 min |
Fluids | 121°C | ~90 min |
Flash Sterilization | 134°C | ~20 min |
Prion Sterilization | 134°C | ~60 min |
Bowie & Dick Test | 134°C | ~35 min |
Vacuum Leakage Test | – | ~25 min |
Number of Optional Programs | – | 99 |
Chamber Dimensions
Chamber Volume (L) | Height (mm) | Width (mm) | Depth (mm) |
125 | 500 | 500 | 500 |
175 | 500 | 500 | 700 |
200 | 500 | 500 | 800 |
225 | 500 | 500 | 900 |
250 | 500 | 500 | 1000 |
325 | 670 | 670 | 750 |
425 | 670 | 670 | 950 |
470 | 670 | 670 | 1050 |
490 | 670 | 670 | 1100 |
538 | 670 | 670 | 1200 |
580 | 670 | 670 | 1300 |
628 | 670 | 670 | 1400 |
670 | 670 | 670 | 1500 |
718 | 670 | 670 | 1600 |
760 | 670 | 670 | 1700 |
800 | 670 | 670 | 1800 |
900 | 670 | 670 | 2020 |
1000 | 670 | 670 | 2250 |
1200 | 670 | 670 | 2675 |
Single Sliding Door Steam Sterilizer Dimensions
Chamber Volume (L) | Height (mm) | Width (mm) | Depth (mm) |
125 | 1800 | 890 | 1250 |
175 | 1800 | 890 | 1300 |
200 | 1800 | 890 | 1350 |
225 | 1800 | 890 | 1400 |
250 | 1800 | 890 | 1500 |
325 | 2010 | 1120 | 1100 |
425 | 2010 | 1120 | 1450 |
470 | 2010 | 1120 | 1550 |
490 | 2010 | 1120 | 1600 |
538 | 2010 | 1120 | 1700 |
580 | 2010 | 1120 | 1800 |
628 | 2010 | 1120 | 1900 |
670 | 2010 | 1120 | 2000 |
718 | 2010 | 1120 | 2100 |
760 | 2010 | 1120 | 2200 |
800 | 2010 | 1120 | 2300 |
900 | 2010 | 1120 | 2500 |
1000 | 2010 | 1120 | 2750 |
1200 | 2010 | 1120 | 2900 |
Power & Volume Specifications
Chamber Volume (L) | Generator Power (3 Phase / 400V ±10%) | Installed Power (3 Phase / 400V ±10%) |
125 | 20 kW | 25 kW |
175 | 30 kW | 35 kW |
200 | 40 kW | 45 kW |
225 | 50 kW | 55 kW |
250 | 60 kW | 65 kW |
Equipment-Related Characteristics
Supply | Pressure (Bars) |
Steam | 4 – 6 Bars |
Generator Volume (L) | Capacity |
60 | Up to 325L |
70 | 425L – 538L |
75 | 580L – 670L |
80 | 718L – 800L |
100 | 900L – 1200L |