ULTRASCAN VIS SPECTROPHOTOMETER-HUNTERLAB

Brand:

Category: Tags: , , Thương hiệu:

The UltraScan VIS utilizes diffuse/8° geometry with the capability to automatically include or exclude the specular component.

With EasyMatch QC software compliant with 21CFR Part 11, it ensures secure and efficient data management. Its robust design, simultaneous measurement of color and gloss, and compliance with numerous international standards make it an ideal solution for quality control.

Explore all the additional features and benefits below.

Measurement Principle: The UltraScan VIS-Hunterlab benchtop colorimeter uses a dual-beam system.

Geometry: Diffuse d/8° reflectance, d/8° total transmission, d/0° regular transmission.

Spectrophotometer/Colorimeter: Two 256-element diode arrays with high-resolution concave holographic grating.

Sphere Diameter: 152 mm (6 in.).

Sphere Coating: Spectraflect™ for the sphere surface, Duraflect™ for the contact surface and specular exclusion door.

Features:

  • Measures reflectance, transmittance, and haze.
  • Wavelength range: 360 nm – 780 nm.
  • 10 nm optical resolution and reporting interval.
  • Two reflectance measurement areas.
  • Exceptional inter-instrument agreement.
  • Automated UV calibration and control.
  • Large transmission compartment open on three sides.
  • Integrated EasyMatch QC software (CFR 21 Part 11)

Specifications:

  • Lens Switching for LAV/SAV: Automatic.
  • Specular Component: Automated inclusion (RSIN) or exclusion (RSEX) in reflectance mode.
  • Spectral Range: 360 nm – 780 nm, full visible range per CIE standards.
  • Wavelength Resolution: < 2 nm.
  • Effective Bandwidth: 10 nm, equivalent triangular shape.
  • Reporting Interval: 10 nm.
  • Photometric Range: 0 to 150%.
  • Photometric Resolution: 0.003% (0.01% reported).
  • Light Source: Pulsed xenon lamp, filtered to simulate D65 daylight.
  • Automatic UV Control:
  • 400 nm cutoff filter for UV control and UV exclusion.
  • Optional 420 nm cutoff filter for UV exclusion.
  • Flashes per Measurement: 1 flash in LAV mode (4 flashes in SAV mode).
  • Measurement Time: < 5 seconds.
  • Transmission Modes: Total Transmission (TTRAN) and Regular Transmission (RTRAN).
  • Transmission Compartment: Large, open on three sides, dimensions 10.2 cm D x 35.6 cm W x 16.5 cm H (4 in. D x 14 in. W x 6.5 in. H).

Port Diameter/View Diameter in RSIN/RSEX Reflectance Modes:

  • Large Area View (LAV): 25 mm (1 in) illuminated/19 mm (0.75 in) measured.
  • Small Area View (SAV): 9.5 mm (0.375 in) illuminated/6 mm (0.25 in) measured.

Port Diameter/View Diameter in TTRAN Transmission Modes:

  • Large Area View (LAV): 25 mm (1 in) illuminated/17.4 mm (0.69 in) measured.
  • Small Area View (SAV): 25 mm (1 in) illuminated/10 mm (0.40 in) measured.

Port Diameter/View Diameter in RTRAN Transmission Mode (Lens as Field Stop for All Viewing Areas):

  • Large Area View (LAV): 17 mm (0.67 in) illuminated/17 mm (0.67 in) measured.
  • Small Area View (SAV): 17 mm (0.67 in) illuminated/17 mm (0.67 in) measured.

Standards Conformance:

  • Reflectance: CIE 15:2004, ISO 7724/1, ASTM E1164, DIN 5033, Teil 7, and JIS Z 8722 Condition C.
  • Transmittance: CIE 15:2004, ASTM E1164, DIN 5033 Teil 7, and JIS Z 8722 Conditions E, G. Haze compliance per ASTM D1003 Section 8, Procedure B for spectrophotometers.
  • Standards Traceability: Instrument standard assignment follows the National Institute of Standards and Technology (NIST) guidelines as described in CIE Publication 44 and ASTM E259.

Sản phẩm đã xem

The UltraScan VIS utilizes diffuse/8° geometry with the capability to automatically include or exclude the specular component. With EasyMatch QC software compliant with 21CFR Part 11, it ensures secure and efficient data management. Its robust design, simultaneous measurement of color and gloss, and compliance with numerous international standards make it an ideal solution for quality control. Explore all the additional features and benefits below.