AGAR PREPARATION PCX- BIOTOOLSWISS

Origin: Switzerland

Category: Tag:

The ProfiClave PCX sets a new standard for automated sterile culture agar preparation. Connected to any BioTool dish filler it provides a reproducible filling and stacking system.

MODEL: PCX

  •  A new space-saving system equipped with everything needed to simplify culture media preparation and speed up the process.
  • Designed for ease-of-use, operation of the PCX is via a large integral screen using a suite of powerful icon-based software that guides you intuitively, with onscreen support, through the culture media preparation process. Operator safety was paramount in the design of the PCX. The pressure vessel closure is automatic and is temperature and pressure dependent.
  • At the heart of the PCX is new thermal boiler heating technology that delivers energy-efficient production and an innovative pre-sterilized auto-lock hose connection that minimizes connection time to your media filler while maintaining a contamination-free environment.
  • The PCX is designed to be economical down to the last milliliter of your culture media, with the sampling tube automatically centering itself at the lowest point of the cuvette.

The brand-new dispensing module DMX for the PCX allows to fill large volumes directly from the media preparator.

With the DMX, you can experience regular and pulsation-free dispensing, making it the ideal solution for storage bottle filling.

Instrument design adapted to laboratory needs, with isolated swing-in pressure cover and easy-to-clean stainless steel surfaces

SPECIFICATIONS 

Harvest Volume up to 15.5 l (1000 dishes – 15 ml)
Residual Volume < 0.20 l
Sterilization Temperature 10 l @ 15 min/121°C: 60–70 min
Temperature Accuracy 80–122°C, ±0.5 °C (độ phân giải: 0.1 °C)
Max. Process Pressure 1.8 bar
Programs >100 programs, 4 access levels (password)
Modes (3) Mediaprep, Autoclave, Agar Melting
Quality of Stainless-Steel (Housing) 1.43301
Quality of Stainless-Steel (Media Contact) 1.4404
Cooling Water 5–30 °C, 0.8–5 bar
Water Connections min. Type III Grade, ¾”
Mains C20 cable connection 16A
Power Consumption max. 3500 W
Operating Voltage* AC 200–240 V ~ 50/60 Hz

*The power supply voltage tolerance is +/- 10 %

Sản phẩm đã xem

A Smarter Rheometer System for QC and R&D The Thermo Scientific™ HAAKE™ MARS™ iQ Rheometer Series enables fast and consistent characterization of a wide range of samples, regardless of the operator. The intuitive software and user-friendly touchscreen help QC and R&D personnel perform standardized operating procedures (SOPs) with ease. Combined with the “Assist” functionalities, the system supports safe and accurate measurements while minimizing measurement errors. Users can choose between two versions equipped with either a ball bearing or an air bearing.

Cone milling is one of the most common methods of milling in the pharmaceutical, food, chemical and associated industries. They are typically used for size reduction and deagglomeration or delumping of powders and granules. Generally used for reducing material to a particle size as low as 180µm (80 mesh) a cone mill produces less dust and heat than alternative forms of milling. The gentle grinding action and quick discharge of correctly sized particles ensure tight particle size distributions (PSDs) are achieved. Cone mill can be used for both wet granulation & dry granulation.

The SFC (Supercritical Fluid Chromatography) system is used for the extraction and purification of compounds. It utilizes supercritical CO₂ to efficiently separate compounds, especially hydrophobic and chiral (optical isomer) compounds. This system is suitable for pharmaceuticals, food, cosmetics, chemicals, and many other industries.

The LEAKSCAN series by DACHTEST offers a comprehensive range of Container Closure Integrity Testing (CCIT) solutions using vacuum decay and pressure decay methods in compliance with USP <1207> and ASTM F2338. This series—spanning from manual (X, XP), semi-automatic (V), to fully automatic (Lab+)—is designed for the pharmaceutical and biopharmaceutical industry, ensuring non-destructive, high-precision leak detection for vials, ampoules, IV bags, prefilled syringes (PFS), and single-use systems.

This advanced chamber is purpose-built to simulate high-temperature, low-oxygen environments for evaluating material durability and oxidation resistance. Featuring a robust triple-layer insulation design and a direct-drive circulation fan, the system ensures uniform conditions throughout the chamber. Its smart control platform integrates real-time sensors, automated data logging, fault detection with alarms, and remote monitoring capabilities—making it an ideal solution for high-precision thermal and oxidative stress testing.

Based on non-contact infrared thermography and 3D heat transfer inverse analysis, the TCA 3DP-160E directly measures in-plane and through-plane thermal conductivity of pouch lithium-ion batteries without sample destruction.   Test Parameters Thermal conductivity   Applications Pouch lithium-ion batteries  

In non-sterile manufacturing processes, where product quality depends on precision and batch-to-batch control, Dara-Lyo has developed a non-sterile freeze dryer with enhanced capacity, suitable for both vial products and bulk products — the LyoLab+ series.

Dissolution tests for high potency drugs with low concentrations of active pharmaceutical ingredients often surpass the capabilities of standard Apparatus 1 or 2 dissolution baths and common analytical instruments. These challenges extend to the dissolution testing of medical devices, microparticles, beads, and topical formulations like creams, gels, and ointments. Distek's Small Volume Conversion Kit provides an ideal solution to these issues, enhancing the accuracy and sensitivity of dissolution tests for these complex samples.

TriEpic has been developed for flexible use with multiple formats and for unlimited freeze-drying processes, when the equipment is required at different times and for different cycles. TriEpic freeze dryers allow simultaneous processing of different formats, as they can be equipped at the same time with rectangular chambers, circular chambers, or stainless-steel manifolds.

error: Content is protected !!