IMAGING MODES- TAPPING MODE- PARK SYSTEMS

Category: Tags: , Thương hiệu:

In this alternative technique to non-contact mode, the cantilever again oscillates just above the surface, but at a much higher amplitude of oscillation. The bigger oscillation makes the deflection signal large enough for the control circuit, and hence an easier control for topography feedback. It produces modest AFM results but blunts the tip’s sharpness at a higher rate, ultimately speeding up the loss of its imaging resolution.

Tapping mode is a dynamic AFM technique that images the sample topography by scanning the surface with an oscillating cantilever.

Similar to Park’s True Non-contact mode, Tapping mode uses the amplitude of cantilever oscillation to detect changes in the tip-sample interaction forces and thereby the sample topography. However, in Tapping mode the cantilever vibrates with larger amplitudes compared to True Non-contact mode and the tip makes intermittent contact with the sample surface during the measurement. The amplitude is used as topography feedback, while the phase lag be-tween drive and detected signal contains information about material-specific mechanical properties. Figure 1 shows the interatomic interaction potential, the so-called Lennard-Jones potential, which is used as approximation for the tip-sample interaction. At short distances between the atoms, the interaction is governed by short-ranged repulsive forces, mainly due to the Pauli repulsion, which prohibits the overlap of electron clouds of tip and sample. Above a certain threshold, attractive van der Waals forces dominate the interaction. Van der Waals forces originate from dipole-dipole interactions.

Figure 1. Interatomic interaction potential U vs. distance r as approximation for the tip-sample interaction. The blue curve represents a purely repulsive interaction, while the red curve represents a purely attractive interaction. The black curve is a combination of long-range attractive and short-range repulsive interaction called the Lennard-Jones Potential. At larger distances, the net force is attractive (-F), which switches to a net repulsive force (+F) when two atoms are brought closer.

Tapping mode operates at the transition between the repulsive and the attractive force regime.

Different from True Non-contact mode measurement, which operates exclusively in the attractive force regime, Tapping mode is an intermittent contact mode, where the tip makes contact to the surface at the lower turning point of the oscillation and, therefore, enters the repulsive force regime.

For the oscillation in Tapping mode, the cantilever is driven close to its resonance frequency f0. The resonance frequency of the cantilever is given by the intrinsic spring constant k0 and the mass m as shown in equation (1). As the cantilever approaches the sample surface, the resonance frequency shifts. This shift is caused by a change of the cantilever spring constant from its intrinsic value to an effective spring constant keff, written as:

At larger tip-sample distances, where attractive forces dominate, the force gradient F’ (=∂F⁄∂Z) is positive and keff becomes smaller than k0 in agreement with equation (2). Accordingly, keff becomes larger than k0 for repulsive tip-sample interaction in proximity of the surface. In Tapping mode, the change of the effective spring constant and, thus, the shift in resonance frequency is detected as a change in the oscillation amplitude. The detection of amplitude changes is more sensitive to the tip-sample distance than changes of the static cantilever deflection.

To introduce the mechanical oscillation of the cantilever a piezo-element with a wide range of frequencies drives the cantilever. The cantilever’s resonance frequency f0 is identified by sweeping the frequency of the drive piezo over certain range and a distinct peak is observed at the resonance. Figure 2 displays the relation between the cantilever’s amplitude and the drive frequency of the cantilever at resonance without interaction forces (a), in the attractive force regime, used for Park’s True non-contact mode (b) and in the transitional force regime between attractive and repulsive forces used for Tapping mode (c).

Figure 2. Schematic of cantilever resonance (a) without tip-sample interaction, (b) for Park’s True Non-contact mode operated in the attractive force regime, leading to shift to lower frequencies in blue, and (c) for Tapping mode operated in the attractive and repulsive force regime, leading to a shift to lower and higher frequencies in blue and red, respectively. The detected change in the oscillation amplitude is indicated as ΔA.

For True Non-contact mode the operating or drive frequency f1 is slightly larger than f0, see figure 2(b). As shown in equations (2) and (3) keff decreases with respect to k0 due to the attractive force, leading to a shift of the resonance to lower frequencies and a negative change in the oscillation amplitude ΔA measured at the frequency f1. For Tapping mode on the other hand, the resonance shifts to lower or higher frequencies within one oscillation cycle as the interaction transitions from the attractive to the repulsive force regime, respectively. Here, the operating frequency f2 is typically lower than f0 to detect the positive and negative change of the oscillation amplitude ΔA in the attractive and repulsive force regime, respectively.

Tapping mode uses the oscillation amplitude detected at the operating frequency as feedback signal. The feedback controls the movement of the Z scanner during imaging to compensate for amplitude variations and thereby distance changes between the tip and the sample. By maintaining a constant amplitude and distance, Tapping mode reconstructs the sample topography from the Z scanner movement.

Figure 3. Schematic diagram of the experimental setup for Tapping mode. The phase between the detected cantilever oscillation and the drive signal gives a contrast between different materials and therefore carries additional information on the material distribution in the sample.

Figure 3 shows a schematic diagram of the experimental setup for Tapping mode. Besides topography measurements, Tapping mode allows imaging of the mechanical and material distribution via the phase signal: due to the intermittent tip-sample contact the phase of the cantilever oscillation with respect to the drive is sensitive to material-specific short-range interactions, such as elasticity, adhesion and stiffness (figure 3). Therefore, the phase signal can visualize mechanical and compositional inhomogeneities in samples. However, since several different effects simultaneously act on the phase signal, phase imaging is limited to qualitative information on the mechanical and material distribution. For quantitative nanomechanical imaging, refer to Park’s PinPoint nanomechanical mode. Figure 4 shows Tapping mode measurements on self-assembled molecule aggregates of the semi-fluorinated alkane F14H20 on a silicon substrate. The AFM height (a) and phase (b) imaged aggregates with sizes between 200 nm and 700 nm in diameter and 4 nm height. Since F14H20 structures are softer than the silicon substrate, they can be clearly distinguished in phase image. The zoom of the phase signal additionally reveals lamellar substructures within the molecule aggregates.

Sản phẩm đã xem

Radwag offers a comprehensive range of moisture analyzers designed to measure moisture content accurately and efficiently in various materials. These instruments cater to industries such as pharmaceuticals, food production, and chemical processing, ensuring precise moisture determination for quality control and process optimization.

Stackable unit design provides space efficiency in daily use. Transparent polycarbonate desiccators are designed for easy viewing of desiccant and vessels.

The SCHMIDT + HAENSCH AutoDosage system is of tremendous help in the workflow of a laboratory. The preparation of samples and dilutions in the laboratory will become perfectly reproducible and accurate, resulting in highest standard laboratory practice and reliable results.

The AS30 HPTLC Sample Applicator is a semi-automatic device that ensures precise and repeatable sample application using advanced spray-on technology to protect the layer integrity and optimize accuracy. Its modular design and compatibility with automation systems like the BS35 auto-sampler make it a cutting-edge solution for high-precision HPTLC analysis.

A Smarter Rheometer System for QC and R&D The Thermo Scientific™ HAAKE™ MARS™ iQ Rheometer Series enables fast and consistent characterization of a wide range of samples, regardless of the operator. The intuitive software and user-friendly touchscreen help QC and R&D personnel perform standardized operating procedures (SOPs) with ease. Combined with the “Assist” functionalities, the system supports safe and accurate measurements while minimizing measurement errors. Users can choose between two versions equipped with either a ball bearing or an air bearing.

Cone milling is one of the most common methods of milling in the pharmaceutical, food, chemical and associated industries. They are typically used for size reduction and deagglomeration or delumping of powders and granules. Generally used for reducing material to a particle size as low as 180µm (80 mesh) a cone mill produces less dust and heat than alternative forms of milling. The gentle grinding action and quick discharge of correctly sized particles ensure tight particle size distributions (PSDs) are achieved. Cone mill can be used for both wet granulation & dry granulation.

The SFC (Supercritical Fluid Chromatography) system is used for the extraction and purification of compounds. It utilizes supercritical CO₂ to efficiently separate compounds, especially hydrophobic and chiral (optical isomer) compounds. This system is suitable for pharmaceuticals, food, cosmetics, chemicals, and many other industries.

The LEAKSCAN series by DACHTEST offers a comprehensive range of Container Closure Integrity Testing (CCIT) solutions using vacuum decay and pressure decay methods in compliance with USP <1207> and ASTM F2338. This series—spanning from manual (X, XP), semi-automatic (V), to fully automatic (Lab+)—is designed for the pharmaceutical and biopharmaceutical industry, ensuring non-destructive, high-precision leak detection for vials, ampoules, IV bags, prefilled syringes (PFS), and single-use systems.

This advanced chamber is purpose-built to simulate high-temperature, low-oxygen environments for evaluating material durability and oxidation resistance. Featuring a robust triple-layer insulation design and a direct-drive circulation fan, the system ensures uniform conditions throughout the chamber. Its smart control platform integrates real-time sensors, automated data logging, fault detection with alarms, and remote monitoring capabilities—making it an ideal solution for high-precision thermal and oxidative stress testing.

Based on non-contact infrared thermography and 3D heat transfer inverse analysis, the TCA 3DP-160E directly measures in-plane and through-plane thermal conductivity of pouch lithium-ion batteries without sample destruction.   Test Parameters Thermal conductivity   Applications Pouch lithium-ion batteries  

In non-sterile manufacturing processes, where product quality depends on precision and batch-to-batch control, Dara-Lyo has developed a non-sterile freeze dryer with enhanced capacity, suitable for both vial products and bulk products — the LyoLab+ series.

Dissolution tests for high potency drugs with low concentrations of active pharmaceutical ingredients often surpass the capabilities of standard Apparatus 1 or 2 dissolution baths and common analytical instruments. These challenges extend to the dissolution testing of medical devices, microparticles, beads, and topical formulations like creams, gels, and ointments. Distek's Small Volume Conversion Kit provides an ideal solution to these issues, enhancing the accuracy and sensitivity of dissolution tests for these complex samples.

TriEpic has been developed for flexible use with multiple formats and for unlimited freeze-drying processes, when the equipment is required at different times and for different cycles. TriEpic freeze dryers allow simultaneous processing of different formats, as they can be equipped at the same time with rectangular chambers, circular chambers, or stainless-steel manifolds.